Delta RMC101 Bedienungsanleitung Seite 252

  • Herunterladen
  • Zu meinen Handbüchern hinzufügen
  • Drucken
  • Seite
    / 951
  • Inhaltsverzeichnis
  • FEHLERBEHEBUNG
  • LESEZEICHEN
  • Bewertet. / 5. Basierend auf Kundenbewertungen
Seitenansicht 251
RMC100 and RMCWin User Manual
5-2
for detail.
Figure #1: SSR switching inductive load; high-side configuration
To calculate the maximum current through the SSR in the above diagram, we assume zero SSR
resistance:
Max. current = 24V / 240W = 100mA
Max. current = 5V / 240W = 20.8mA
In the 24V case, the maximum current is right at the maximum allowed by the SSRs. The outputs
may be overpowered if the coil resistance is reduced further. To calculate the typical current
through the SSR, we use the typical SSR resistance of 25W:
Typical current = 24V / (240W + 25W) = 90.6mA
Typical current = 5V / (240W + 25W) = 18.9mA
Seitenansicht 251
1 2 ... 247 248 249 250 251 252 253 254 255 256 257 ... 950 951

Kommentare zu diesen Handbüchern

Keine Kommentare