undercurrent or instantaneous overcurrent trip levels. The
flags can signal the situation to external equipment via one
of the programmable outputs. The flags clear when the
current returns within the normal operating range by 10% of
the programmed motor full load current.
4
4-10 Low Current Flag
Range: Function:
50%* [1% - 100% FLC] Sets the level at which the low current
flag operates, as a percentage of motor
full load current.
4-11 High Current Flag
Range: Function:
100%* [50% - 600%
FLC]
Sets the level at which the high current
flag operates, as a percentage of motor
full load current.
7.7.4 Motor Temperature Flag
The MCD 500 has a motor temperature flag to give early
warning of abnormal operation. The flag can indicate that
the motor is operating above its normal operating
temperature, but lower than the overload limit. The flag can
signal the situation to external equipment via one fo the
programmable outputs.
4-12 Motor Temperature Flag
Range: Function:
80%* [0% - 160%] Sets the level at which the motor
temperature flag operates, as a percentage
of the motor's thermal capacity.
7.7.5 Analog Output A
The MCD 500 has an analog output, which can be connected
to associated equipment to monitor motor performance.
4-13 Analog Output A
Option: Function:
Selects which information will be reported via
analog output A.
Current (%
FLC)
Current as a percentage of motor full load current.
Motor
Temp (%)
Motor temperature as a percentage of the motor
service factor (calculated by the soft starter's
thermal model).
Motor kW
(%)
Motor kilowatts. 100% is motor FLC (Par. 1-1)
multiplied by mains reference voltage (Par. 8-9).
Power factor is assumed to be 1.0.
í
9
í
,
)/&
í
SI
Motor kVA
(%)
Motor kilovolt amperes. 100% is motor FLC (Par.
1-1) multiplied by mains reference voltage (Par.
8-9).
4-13 Analog Output A
Option: Function:
í
9
í
,
)/&
Motor pf Motor power factor, measured by the soft starter.
4-14 Analog A Scale
Option: Function:
Selects the range of the output.
0-20 mA
4-20 mA
4-15 Analog A Maximum Adjustment
Range: Function:
100%* [0% - 600%] Calibrates the upper limit of the analog
output to match the signal measured on an
external current measuring device.
4-16 Analog A Minimum Adjustment
Range: Function:
0%* [0% - 600%] Calibrates the lower limit of the analog output
to match the signal measured on an external
current measuring device.
7.8 Start/Stop Timers
CAUTION
The auto-start timer overrides any other form of control. The
motor may start without warning.
5-1 Auto-Start Type
Option: Function:
Selects whether the soft starter will auto-start after a
specified delay, or at a time of day.
Off
The soft starter will not auto-start.
Timer The soft starter will auto-start after a delay from the next
stop, as specified in Par. 5-2.
Clock The soft starter will auto-start at the time programmed in
Par. 5-2.
5-2 Auto-Start Time
Range: Function:
1 min* [00:01 - 24:00
(hrs:min)]
Sets the time for the soft starter to
auto-start, in 24 hour clock format.
5-3 Auto-Stop Type
Option: Function:
Selects whether the soft starter will auto-stop after a
specified delay, or at a time of day.
Off
The soft starter will not auto-stop.
Time The soft starter will auto-stop after a delay from the next
start, as specified in Par. 5-4.
Clock The soft starter will auto-stop at the time programmed in
Par. 5-4.
Programming MCD 500 Operating Instruction