Delta RMC70 Bedienungsanleitung Seite 33

  • Herunterladen
  • Zu meinen Handbüchern hinzufügen
  • Drucken
  • Seite
    / 48
  • Inhaltsverzeichnis
  • LESEZEICHEN
  • Bewertet. / 5. Basierend auf Kundenbewertungen
Seitenansicht 32
Appendix A: Wiring
deltamotion.com 31
MA Module Start/Stop or PWM Transducer Wiring
For magnetostrictive transducers with Start/Stop or PWM outputs.
12-pin Axis
Connector
Interrogate +
Interrogate -
Return +
Return -
Power Supply
+Pwr
Cmn
Int/Clk+
Int/Clk-
Cmn
Ret/Dat+
Ret/Dat-
Case
Pwr+
DC Ground
Tip: See next page for manufacturer-specific wiring diagrams.
Notes:
The MA module interfaces to 5V differential (RS-422) signals.
Single-ended (TTL) transducers are not supported.
The Cmn pins on the 12-pin connector are electrically identical.
The user must supply power to the transducer.
Do NOT connect the transducer ground or common to the
shield, case, or protective earth ground.