TROUBLE SHOOTING GUIDE
Check to ensure faucet was installed
according to the M&I sheet.
Test for operation. If unit does not
operate:
If faucet shuts off due to interference:
If the faucet does not work properly, follow the steps below in order.
Step 1
Note: See instructions on pages 1 to 4.
Check to be sure that white sensor wire is firmly connected to the thin
capacitance tab, and that the nut and washer are firmly connected to
the underside of the counter top. See Fig. 1 on page 2.
Check to be sure power cable is properly secured in fitting.
Check to be sure batteries are fresh and properly installed.
Check two wires to solenoid to be sure they are connected correctly.
Check to be sure water supply is turned on.
When the faucet detects an object for longer than 45 seconds, or if
faucet self-cycles for 4 times within 15 seconds, it will automatically shut
off. This will be followed by 3 quick beeps which indicate that calibration
is about to take place. The faucet will then enter calibration per step 7b.
Once calibration takes place (with no user present) the faucet will return
to regular operation.
Faucet makes a beeping noise.
(Different from re-calibration in step 1):
Step 2
BATTERY POWERED: Faucet beeps twice when turning off:
indicates batteries are low and need to be replaced (1500 cycles or 2
weeks left). Faucet beeps continuously when hands in front of
spout and no water: faucet locked out because batteries are too low.
HARDWIRE: Check voltage from converter and transformer. It should
be approximately 6.4 volts DC coming from converter to the driver
board.
Replace batteries.
Replace batteries.
Replace Hardwire
converter 060683A, if
required.
The faucet stops working. No water flow.
Check the function of the solenoid.
Step 3
The solenoid should “click” when activated.
Clean as required.
Correct as required.
If there is a
clicking sound:
If no clicking
sound:
This indicates that both the sensor and the solenoid are functioning.
Ensure inlet screen on solenoid is not plugged with debris.
Check the incoming water supply. Turned on, proper pressure and
volume, etc.
Check for a pressure lock between the mixing valve and the solenoid.
Turn off the water supply and undo the connection to the inlet of the
solenoid, this will eliminate any built-up pressure.
Then activate sensor and test fire the solenoid.
If after above there is no clicking sound;
Defective solenoid.
Replace 060910A
Solenoid.
If faucet does not activate or works
erractically:
Step 4
If after completion of all above steps, the valve still does not function correctly; Call Technical Service for further assistance at 1-800-387-8277.
Step 5
Check for electrical interference.
Check for interference from other electrical devices within close
proximity to the spout or battery box. Devices such as other infrared
devices, transformers, etc.
Excessive water on the counter top may lead to an overly sensitive
faucet. Wipe water off, re-calibrate the faucet.
Re-calibrate the unit by disconnecting the batteries for 10 seconds, then
reconnecting. Follow steps 7a and 7b of the Installation and Set-Up
Instructions.
BATTERY and HARDWIRE POWERED: When battery connection is
touched, it trips the electronics and turns on the solenoid.
Call Technical Service if
any such conditions
found. 1-800-387-8277.
This Delta Commercial faucet is designed and engineered in accordance with the highest quality and performance standards. With
proper care, it will give you years of trouble free service. Care should be given to the cleaning of this product. Although the chrome
finish is extremely durable, it can be DAMAGED by ACIDIC CLEANERS (i.e., cleaners designed specifically for vitreous china
lavatories and water closets), HARSH ABRASIVES or POLISH. To clean, simply wipe the surface with a damp cloth and blot dry with
a soft towel.
CARE INSTRUCTIONS
BATTERY POWERED: Check to ensure all batteries are inserted
correctly.
HARDWIRE: Check voltage from converter to transformer.
Ensure battery polarities
are correct and that
voltage is sufficient -
around 6 volts.
Continuous beeping tone upon power-up:
Water runs non stop when batteries are
disconnected:
When disconnecting the
power, grab the battery
clip and wait for at least
one full second before
disconnecting it.
Solenoid will shut off
after power disconnected.
Seitenansicht 4