Delta RPI-H3 Wartungshandbuch

Stöbern Sie online oder laden Sie Wartungshandbuch nach Netzteile und Wechselrichter Delta RPI-H3 herunter. Delta RPI-H3 Technical data Benutzerhandbuch

  • Herunterladen
  • Zu meinen Handbüchern hinzufügen
  • Drucken

Inhaltsverzeichnis

Seite 2 - Contents

4 2. Installation and Wiring 2.1 Instruction before Installation Due to variety of users’ installation environment, reading this manual

Seite 3

5 2.3 Package Inspection Unknown situations may occur during shipments. Please check if there is any damage on the wooden carton. After opening the p

Seite 4

6 2.4 Identification Label Users can identify the model number by the information on the product label. The model number, specifications as well

Seite 5 - Figure Index

7 3. Product Overview 3.1 Dimension Figure 3-1 Dimension of RPI-H3 Figure 3-2 Dimension of RPI-H5

Seite 6 - Table Index

8 3.2 Function Introduction Inverter’s exterior objects are shown on the Figure 3-3, and the detailed description is in sections 3.2.1 and 3.2.2. F

Seite 7 - General Information

9 3.2.2 Inverter Input/Output Interface Figure 3-5 Input/Output interface

Seite 8 - 1.5 How it Works

10 !!4. Installation 4.1 Installation Location WARNING!!!! Death and serious injuries may occur. ● Do not install the unit near/on the

Seite 9 - 1.6 Additional Information

11 Figure 4-1 Screw the mounting bracket for RPI-H3

Seite 10 - 2.2 Unpacking

12 Figure 4-2 Screw the mounting bracket for RPI-H5

Seite 11 - 2.3 Package Inspection

13 ! Figure 4-3 Correct and incorrect installation illustration CAUTION  The location and hardware should be a solid surface or a firm holder tha

Seite 12 - Identification Label

i Contents 1. General Information ... 1 1.1 About this Manual ...

Seite 13 - 3. Product Overview

14  Ambient temperature -20℃~60℃.(power derating above 40℃) There shall be sufficient space for product operation as shown as the Figure 4-4. If

Seite 14 - 3.2 Function Introduction

15 !5. Wiring 5.1 Preparation before Wiring 1. Make sure whether the voltage values, polarities are correct. 2. When grounding of the solar array i

Seite 15

16 5.2 AC Grid Connection: L + N + PE WARNING! Death and serious injuries may occur. Before AC wiring, please ensure AC breaker is switched off.

Seite 16 - 4. Installation

17 !! Figure 5-3 AC plug illustration  The AC voltage should be as following. L-N: 230 Vac± 10 5.3 DC Connection (from PV Array) WARNING

Seite 17

18 (RPI-H3) / 5950W (RPI-H5). ◆ The device installed between PV Array and inverter must meet the rating of voltage higher than this device’s maximum

Seite 18

19 5.4.1 RS-485 Connection The pin definition of RS-485 is shown as in Table 5-2 and protocol settings are listed in Table 5-3. The wiring of multi-i

Seite 19

20 6. Active/Reactive Power Control and Low Voltage Ride Through (Optional) There are 2 settings for active power and 4 settings for reactive p

Seite 20

21 Power vs. frequency curve for VDE-AR-N 4105 Power vs. frequency curve for CEI-021 Figure 6-1 Power vs. frequency characteristic 6.2 Reac

Seite 21 - 5. Wiring

22 target value variably adjustable by remote control (or other control technologies) will be specified by the network operator in the trans

Seite 22

23 6.2.4 Reactive Power / Voltage Characteristic Q(U)(CEI 0-21) Once user enables this method, user can set Q vs. Grid voltage operation

Seite 23

ii 6.1.1 Power Limit ...20 6.1.2 Power vs. Frequency ...

Seite 24 - 5.4 Communication Module

24 6.3 Low Voltage Ride Through (LVRT) According to CEI 0-21, 8.5.1 To avoid undue separation from the network if voltage dips occur, a generation

Seite 25 - 5.4.1 RS-485 Connection

25 7. Turn on/off PV inverter WARNING::::BURN HAZARD The enclosure temperature may exceed over 70 ℃ while operating. Da

Seite 26 - 6.1.2 Power vs. Frequency

26 7.2 Inverter Setting 7.2.1 Country Setting The first time you startup this device. Country Setting is required. 1. In the country setting p

Seite 27 - Reactive Power Control

27 Figure 7-2 AC Configuration Setting-1

Seite 28

28 SELxxxxxxN e x t / E n t e rxxxxxxN / YSELENTENTSELENTExit ?N / YENTSELxxxxxxN e x t / E n t e rInstal

Seite 29

29 7.2.3 Connecting the Communication Wiring Multiple inverters could be monitored via RS-485 connection (Figure 5-6), but each inverter’s ID must be

Seite 30

30 O u t p u t 3 6 0 0 W T o d a y 7 2 0 0 W hO u t p u t C u r r e n t1 6 . 0 AU t i l i t y2 2 5 V 6 0 . 0 0 H z D C :

Seite 31 - 7. Turn on/off PV inverter

31 Page6 Total output energy Page7 Total input energy Page8 Start page Page9 Firmware version Page10 Event list Page11 Inverter ID Page12 Coun

Seite 32

32 N E T H E R L A N D SN e x t / E n t e rB E L G I U MN e x t / E n t e rX X X X X XN e x t / E n t e rN E T H

Seite 33

33 7.3.3 Language Selection When entering this page, user can set five different languages. Figure 7-8 Language selection Table 7-2 Language lis

Seite 34

iii Appendix A : Multi-function Relay ... 47 A.1 Multi-function relay output connection ...

Seite 35 - 7.3 LCD flowchart

34 7.3.4 Insulation Mode Figure 7-9 Insulation mode 7.3.5 Settings Setting includes Personal Setting, Coefficients Setting, Install Setting and

Seite 36 - Relay On

35 7.3.6 Italy Self-test Italy Self-test includes Uac High(UH), Uac Low(UL), Fac High(FH) and Fac Low(FL). User can choose the selection of

Seite 37 - 7.3.2 Country Selection

36 8. Maintenance In order to ensure the normal operation of PV Inverter, please check up regularly at least once each year or each hal

Seite 38 - Country is Default

37 U t i l i t y2 2 5 V 6 0 . 0 0 H z3O u t p u t 3 6 0 0 W T o d a y 7 2 0 0 W h12O u t p u t C u r r e n t1 6 . 0 A4 D C :

Seite 39 - 7.3.3 Language Selection

38 9.2 Error Message & Trouble Shooting Table 9-2 Error message ERROR Message Possible cause Action E01: Grid Freq Over Rating 1. Actual ut

Seite 40 - 7.3.5 Settings

39 setting 4. Detection circuit malfunction 4. Check the detection circuit inside the inverter E13: Slow Over Voltage Range 1. Actual utility voltage

Seite 41 - 7.3.6 Italy Self-test

40 A05: NTC Over Temp 1. The ambient temp. is over 60℃ 2. Detection circuit malfunction 1. Check the installation ambient and environment 2. Chec

Seite 42 - 8. Maintenance

41 Inconsistent defective the inverter A22: Internal Comm Fault_R 1. Red. CPU is idling 2. The communication connection is disconnected 1. Check res

Seite 43 - Trouble Shooting

42 3. Driver for boost is defective or disconnected 4. Detection circuit malfunction the inverter 4. Check the detection circuit inside the inverter

Seite 44 - Table 9-2 Error message

43 Sensor Fail 3. Detection circuit malfunction 3. Check the detection circuit inside the inverter A45: HW OOCP 1. WB1 WB2 misconnection. 2. Detectio

Seite 45 - Over Rating

iv Figure Index Figure 1-1 Solar inverter system operation illustration...2 Figure 2-1 Unpacking process ...

Seite 46

44 !10. De-Commissioning De-Commissioning Procedure If it is necessary to put the device out of operation for RMA or maintenance, please follow the

Seite 47

45 11. Technical Data 11.1 Specifications Table 11-1 Specifications RPI-H3 RPI-H5 GENERAL Enclosure Powder coated aluminum Operating temperat

Seite 48

46 Fuse Internal fuse, 20 A/250 V*1 Internal fuse, 20 A/250 V*2 MECHANISM Housing Aluminum Extrude Cooling Natural cooling IP rating IP65 External

Seite 49

47 Appendix A Multi-function Relay Inverter support one multi-function relay, the multi-function relay is available to external devices. The devic

Seite 50 - 10. De-Commissioning

48 ! Figure A-2 Dry contact location Danger !!!!Hazard of Electric shock. Touching electronic components can damage compo

Seite 51 - 11. Technical Data

49 Appendix B Digital Input To implementation of power management, the digital input interface receives the specifications of the network operator

Seite 52 - Internal fuse, 20 A/250 V*2

50 Pin Function 1 Digital input 1 2 Digital input 2 3 Digital input 3 4 Digital input 4 5 Output 1 6

Seite 53 - Appendix A

v Table Index Table 2-1 Packing list ...5 Table 5-1 AC wire requi

Seite 54

1 !!1. General Information 1.1 About this Manual This manual provides the detailed information of specification, installation procedures

Seite 55 - Appendix B

2 1.4 Product Description This device is a single phase grid-tie solar inverter. It converts direct current (DC) electricity from photovoltaic power

Seite 56

3 1.6 Additional Information For more detailed information for RPI-H3/RPI-H5 or other related product information, please visit http://www.deltaww.co

Kommentare zu diesen Handbüchern

Keine Kommentare